DC Inverter Air Cooled Scroll Drinking water Chiller
Merchandise characteristics
Higher effectiveness
A++ rated vitality effectiveness
Structure
Panels and foundation body are manufactured from galvanized metal safeguarded with polyester powder painting to guarantee overall resistance to atmospheric agents.
Compressor
Entire world-major DC inverter compressor. The compressor’s revolutionary layout and several large efficiency features decrease electricity use by twenty five%.
> Rotary compressor for 60kW
> Scroll compressor for 65kW~150kW
Axial supporter
External rotor variety axial followers, outfitted with solitary stage direct drive motors, lower sound 6 poles, security amount IP54, plastic blade for minimal noise.
Evaporator
> Plate warmth exchanger for AW60/AW90
Substantial performance plate warmth exchanger, manufacturing facility insulated with adaptable shut mobile materials.
> Shell and tube warmth exchanger for AW65/AW130/AW150
For shell-tube heat exchanger, the module adopts the new helical baffle style to stay away from the rectangular place of water lifeless zone, drastically boost the heat exchange effectiveness.
Condenser
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins, guarded with flexible plastic grill.
The new developed window fins enlarge the heatexchanging area, reduce the air resistance,help save much more electrical power and increase warmth trade functionality.
Hydrophilic movie fins and interior-threaded copper pipes improve heat trade performance.
The specially coated blue fins enhance sturdiness and defend against corrosion from air, drinking water and other corrosive brokers, assures a longer coil services lifestyle.
Precisely movement manage
Patented liquid distribution parts increase performance and lessen effect of defrosting procedure. 500-phase EXV with capillary tube permits secure and exact gas flow control.
Rapidly response outcomes in higher effectiveness and enhanced reliability.
Straightforward manage
Touch important wire controller as standard accent to handle the chillers.
Modbus operate, it is an open protocol that is extensively utilised, specifically in BMS developing management techniques. It can connect Max. 16 wired controllers and every single controller can handle Max. 16 units.
Optional
CZPT module, such as movement switch, water pump and growth vessel (For model AW60/AW90 only).
Specifications
Product | AW60 | AW65 | AW90 | AW130 | AW150 | ||
Potential | Cooling | kW | fifty five | sixty five | 82 | a hundred thirty | a hundred and fifty |
Power input | kW | 22 | 19.2 | 36.8 | 38.5 | 47.five | |
EER | two.5 | three.39 | 2.23 | three.38 | 3.sixteen | ||
Heating | kW | sixty one | 68 | ninety | 136 | 150 | |
Power input | kW | 20.three | 21.four | 32.eight | forty two.eight | 47.2 | |
COP | 3.00 | three.eighteen | 2.seventy four | three.eighteen | three.18 | ||
Compressor | Sort | Rotary | Scroll | Scroll | Scroll | Scroll | |
Qty | 2 | 2 | 2 | 4 | 4 | ||
Axial fan | Kind | DC motor | AC motor | DC motor | AC motor | ||
Qty | 2 | two | three | 4 | four | ||
Air circulation charge | 24000 | 28600 | 38000 | 57200 | 57200 | ||
Control methods | EXV+Capillary | EXV | |||||
Evaporator type | Plate heat exchanger | Shell and tube heat exchanger | Plate heat exchanger |
Shell and tube heat exchanger |
|||
Water flow | m3/h | 9.eight | 11.18 | fifteen | 22.36 | twenty five.eight | |
Pipe connection size | DN | 50 | 50 inner screw | fifty | sixty five flange | sixty five flange | |
Water resistance | kPa | sixty one | fifty five | seventy five | fifty five | sixty eight | |
Refrigerant Type | R410A | ||||||
Charge quantity | kg | seventeen | 9×2 | 27 | 9×4 | 9.5×4 | |
Power supply | 380~415V/3Ph/50Hz | ||||||
Web dimensions (W×H×D) | mm | 2220x1055x1325 | 2571x996x2240 | 3220x1095x1513 | 2076x1971x2240 | 2076x1971x2240 | |
Unit shape | Horizontal | Vertical | Horizontal | Vertical | Vertical | ||
Noise level | dB(A) | 87 | sixty eight | 89 | 71 | seventy one | |
Net Weight | kg | 480 | 490 | 710 | 954 | 974 |
Note:
one. Cooling: Chilled drinking water inlet/outlet temp.twelve/7°C outdoor ambient temp. 35°C DB.
two. Heating: Heat drinking water inlet/outlet temp. forty/45°C outside ambient temp. 7°C DB/6°C WB.
three. Audio force level is calculated at a placement 1m in entrance of the unit and 1.1m over the flooring in a semi-anechoic chamber.
four. Ability and performance data calculated in accordance with EN14511 EN14825.